IBM Support

IC74959: GENERATING TWO ERROR REPORTS IN THE SAME SECOND MAY CAUSE DUPLICATE SNMP TABLE INDEXES IN FAILURENOTIFICATIONSTATUS TABLE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as fixed if next.

Error description

  • There is the possibility that a duplicate SNMP table index may
    occur if two error reports are generated in the same
    second.  This can potentially happen during the redirect of an
    error report when the original destination failed.  If a
    duplicate SNMP table index created, it will cause a failure in
    the SNMP Get-Bulk operation.
    

Local fix

  • No Work-Around.
    

Problem summary

  • This will be fixed in a future release.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IC74959

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    381

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-03-10

  • Closed date

    2011-04-06

  • Last modified date

    2011-06-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

  • R381 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.8.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]