  • Installed the latest PCOM 6.0.2.0 on a Win7 image.  It seems
    like there is a change in the way PCOM reads the pcswin.ini
    file. We have
    
    [View1]
    Description=Startup
    
    defined in the pcswin.ini file.  We use the "start-up.bch" file
    to launch the PCOM sessions.
    
    If [LastExitView] exists in the pcswin.ini, PCOM seems to ignore
    the defined "Startup" view and it also launches PCOM printer1.ws
    in the foreground.
    
    If [LastExitView] does NOT exist in the pcswin.ini, then PCOM
    sessions are opened as expected.
    
    This only happens in PCOM 6.0.2.0.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: Saved view does not work from BCH file  *
    *                      or command line.                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When a view is specified in command line or in a BCH file it
    is being overridden by the LastExitView function.
    

Problem conclusion

  • PCSWS.EXE has been changed to not run LastExitView when a
    saved view is used with a BCH file or command line to start
    emulator sessions.
    
    Fix scheduled for PCOM 5.9.8 Manufacturing Refresh
    Fix scheduled for PCOM 6.0.3 Manufacturing Refresh
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC74619

  • Reported component name

    PCOMM V5 COMBO-

  • Reported component ID

    5639I7000

  • Reported release

    601

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-02-21

  • Closed date

    2011-02-22

  • Last modified date

    2012-05-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • PCSWS
    

Fix information

  • Fixed component name

    PCOMM V5 COMBO-

  • Fixed component ID

    5639I7000

Applicable component levels

  • R590 PSY IP23349

       UP12/05/09 I 1000

  • R600 PSY

       UP

  • R601 PSY

       UP

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSEQ5Y","label":"Personal Communications"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.1","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
06 January 2022