A fix is available
APAR status
Closed as program error.
Error description
After setting the TextFitMaxWindow=N in the Work Station profile, the screen data incorrectly shifted left.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users with screen resolution greater * * than 1280x... * **************************************************************** * PROBLEM DESCRIPTION: User starts a session which has * * TextFitMaxWindow=N set in the profile * * then maximized the Window and close it. * * Restart the same session, the screen * * text will shift to the left. * **************************************************************** * RECOMMENDATION: * **************************************************************** The screen text is shifted to the left due to LastExitView being reprocessed when the screen is maximized. This happens on Japanese display sessions using TextFixMaxWindow=N keyword or non-Japanese display sessions that do not use the keyword but only if the resolution is greater than 1280xn.
Problem conclusion
PCSWS.EXE has been changed to not reprocess LastExitView when the display session Window is maximized. Fix scheduled for PCOM 5.9.8 Manufacturing Refresh Fix scheduled for PCOM 6.0.3 Manufacturing Refresh
Temporary fix
Comments
APAR Information
APAR number
IC74568
Reported component name
PCOMM V5 COMBO-
Reported component ID
5639I700J
Reported release
600
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-02-18
Closed date
2011-02-22
Last modified date
2012-04-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
PCSWS
Fix information
Fixed component name
PCOMM V5 COMBO-
Fixed component ID
5639I700J
Applicable component levels
R590 PSY
UP
R600 PSY IP23353
UP12/04/26 I 1000