IBM Support

IC74479: ODCINFO SERVLET MAY NOT POPULATE COOKIENAMES VALUE PROPERLY UNLESS THE APPLICATION IS RESTARTED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The ODCInfo Servlet used with the Application Optimization
    feature for Intelligent Load Distribution may fail to populate
    the cookieNames value if a cluster has been started after the
    servlet was started.
    
    If the application is running and the cluster is
    subsequently started, then the output of:
    
    http://dm_hostname:dm_port/ODCInfo/ODCInfo?c=clusterName
    
    may show:
    
    <cookieNames value="null"/>
    
    instead of an expected value like:
    
    WSJSESSIONID,JSESSIONID,SSLJSESSIONID.
    

Local fix

  • The problem resides in the ODCInfo servlet that is retrieving
    the cluster information including server hostnames, ports,
    weights, and session affinity.   The ODCInfo servlet is shipped
    in the resource kit.   The customer must uninstall the ODCInfo
    servlet and OSGi bundle, and must install the ODCInfo servlet
    and OSGi bundle from one of the following resource kits:
    DataPower-3.8.1.11-XI50-Resource-Kits
    DataPower-3.8.1.11-XS40-Resource-Kits
    DataPower-3.8.2.3-XI50-Resource-Kits
    DataPower-3.8.2.3-XS40-Resource-Kits
    

Problem summary

  • Session Affinity is not properly updated when a new cluster is
    brought on line.
    

Problem conclusion

  • The fix will be in 3.8.1.11 & 3.8.2.3
    

Temporary fix

  • Restart the ODCInfo Application and all values associated with
    all clusters will be correctly retrieved.
    

Comments

APAR Information

  • APAR number

    IC74479

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    381

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-02-15

  • Closed date

    2011-04-15

  • Last modified date

    2011-04-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R381 PSY

       UP

  • R382 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.8.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
11 February 2022