IBM Support

IC74178: CUSTOMER FTP REPLY MESSAGE NOT RETURNED WHEN FTP FSPH HAS A FILESYSTEM TYPE OF TRANSPARENT.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When putting files to a DataPower FTP Server FSPH (Front-side
    Protocol Handler), a
    custom reply message is expected to be returned by utilizing the
    DataPower service variables
    
    var://service/error-protocol-response
    
    and
    
    var://service/error-protocol-reason-phrase.
    
    The expected reply message is returned fine when the DataPower
    FTP FSPH has a filesystem type of virtual ephemeral but not when
    the filesystem type is transparent.
    

Local fix

  • No Work-Around
    

Problem summary

  • Affected are customers using FTP Front-side Protocol Handlers
    with filesystem type of TRANSPARENT.
    
    Custom reply messages are not returned to the FTP client for
    filesystem type transparent.
    

Problem conclusion

  • The fix is available in 3.7.3.17, 3.8.0.11, 3.8.1.10, 3.8.2.2
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC74178

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    373

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-01-27

  • Closed date

    2011-02-23

  • Last modified date

    2011-02-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R373 PSY

       UP

  • R380 PSY

       UP

  • R381 PSY

       UP

  • R382 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.7.3","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]