IBM Support

IC71988: FTPS DATA CONNECTIONS MAY TERMINATE WITH ERROR 522 CERTIFICATE MISMATCH

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The DataPower FTPS front side handler may error out
    
    
    if the data channel tries and fails to verify the client
    certificate before the client has been able to send the
    certificate. The following error will be thrown.
    
    522 certificate mismatch between control and data connections.
    

Local fix

Problem summary

  • When using SSL use a fixed 10 second timeout to wait for SSL
    negotiation to complete on the data connection.
    

Problem conclusion

  • The fix will be in 3.8.0.9 & 3.8.1.7
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC71988

  • Reported component name

    DATAPWER B2B XB

  • Reported component ID

    DP1234B2B

  • Reported release

    373

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-10-19

  • Closed date

    2010-11-29

  • Last modified date

    2010-12-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPWER B2B XB

  • Fixed component ID

    DP1234B2B

Applicable component levels

  • R380 PSY

       UP

  • R381 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSQ3J2","label":"WebSphere DataPower B2B Appliance XB60"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.7.3","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: