IC70228: ONPLOAD SEGV DUE TO STACK OVERFLOW SOON AFTER FORKING A CONVERT THREAD AND ADDING A NEW ONPLOAD SHARED MEMORY SEGMENT

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as fixed if next.

Error description

  • In certain circumstances, an onpload frontend thread may
    overflow its stack.  This problem is more likely to be seen on
    HP Itanium.  You need a new onpload shared memory segment to be
    added at the same time as the fork of the new convert thread for
    the problem to occur.
    
    By onpload shared memory segments, I mean the onpload private
    shared memory segments that start with 0x49 key --
    
    Example:
    
    $ ipcs -m | grep 0x49
    
    m    6094866 0x49010000 --rw-rw----  informix  informix  <---
    onpload R segment
    m    5668883 0x49010001 --rw-rw----  informix  informix  <---
    onpload initial V segment
    m    5931028 0x49010002 --rw-rw----  informix  informix  <---
    onpload new V segment added after startup
    
    Note:  The onpload stack size and the sizes of the onpload
    segments are not configurable.
    
    The problem occurs rarely and randomly during onpload job start
    -- when the problem segv does occur, if you have tracing turned
    on, you will see a line like this in the trace file:
    
    02:29:28 - FORKED(worker, 12): convert 25
    ...
    02:29:28 - plsig_segv(convert, 25): signal received
    
    
    If you do not have tracing turned on, you may see a plsig_segv()
    message in stderr/stdout, but it probably will not say where it
    came from.
    
    The same job, when re-run may not run into the problem again.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Informix 11.50, HP-UX Itanium 11.23                          *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * onpload may crash or hang shortly after a new shared memory  *
    * segment is added.                                            *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to Informix 11.50.xC8 or higher.                     *
    ****************************************************************
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IC70228

  • Reported component name

    IBM IDS ENTRP E

  • Reported component ID

    5724L2304

  • Reported release

    B15

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-07-27

  • Closed date

    2011-01-20

  • Last modified date

    2011-01-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

  • RB15 PSN

       UP

  • RB15 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSGU8G","label":"Informix Servers"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B15","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]