IC61218: CHECKIN LIBVOL FAILS WITH ANR8300E ON LIBRARY WITH LARGE NUMBER OF STORAGE SLOTS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When checking in volumes using checkin libvol or label libv
    with the checkin parameter, and the search=yes parameter is
    also used, ANR8300E can occur on libraries which have a large
    number of storage slots. The tape library must be controlled
    by the TSM device driver for this apar to apply.
    -
    The problem is that the TSM device driver will time out the
    checkin command if it runs longer than 30 minutes.
    These messages will occur in the activity log if this
    problem exists:
    -
    05/18/2009 14:48:05 ANR2017I Administrator ADMIN issued
    command CHECKIN libv LIBRARY search=yes status=private
    checkl=barcode (SESSION: XXXX)
    05/18/2009 15:18:06 ANR8300E I/O error on library LIBRARY
    (OP=00006C04, CC=205, KEY=FF, ASC=FF, ASCQ=FF, SENSE=**NONE**,
    Description=SCSI adapter failure).
    Refer to Appendix C in the 'Messages' manual for recommended
    action. (SESSION: XXXX, PROCESS: XX)
    -
    Timestamps for the error should be 30 minutes apart.
    -
    Notes:
    1. ANR8300E can occur for other reasons. The ASC, ASCQ and
    lack of sense data need to exist, as well as the 30 minute
    time period for the problem to match this apar.
    -
    2. A similar problem can exist for tape libraries which are
    controlled by the IBMtape device driver. The fix for the
    problem in this apar does not affect similar problems on
    IBMtape controlled libraries. IBMtape support should be
    engaged if this problem is encountered with an IBMtape
    controlled library. See knowledge document 1368357.
    Tivoli Storage Manager Versions Affected:
    5.4, 5.5, and 6.1 servers on all platforms with scsi tape
    libraries controlled by the TSM device driver
    Initial Impact:
    Medium
    Additional Keywords:
    MSGANR8300E sense asc ascq tsmdd tsmscsi ddtrace 1368357 zz61
    

Local fix

  • Check in tapes using the bulk option. On Quantum libraries,
    and option called "touch teach" may cause the checkin to
    run longer. Disabling this option may reduce the time
    required to do the checkin.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Tivoli Storage Manager users of an           *
    *                 ADIC/Quantum Scalar 10K library equipped     *
    *                 with a large number of storage slots.        *
    ****************************************************************
    * PROBLEM DESCRIPTION: See ERROR DESCRIPTION                   *
    ****************************************************************
    * RECOMMENDATION:   Apply fixing level when available. This    *
    *                   problem is currently projected to be fixed *
    *                                                              *
    *                   in level 5.4.6, 5.5.3, and 6.1.2.          *
    *                   Note that this is subject to change at the *
    *                                                              *
    *                   discretion of IBM.                         *
    ****************************************************************
    *
    

Problem conclusion

  • The problem was fixed in the Tivoli Storage Manager device
    driver.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC61218

  • Reported component name

    TSM SERVER

  • Reported component ID

    5698ISMSV

  • Reported release

    55A

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-05-20

  • Closed date

    2009-05-27

  • Last modified date

    2009-05-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TSM SERVER

  • Fixed component ID

    5698ISMSV

Applicable component levels

  • R54A PSY

       UP

  • R54H PSY

       UP

  • R54L PSY

       UP

  • R54S PSY

       UP

  • R54W PSY

       UP

  • R55A PSY

       UP

  • R55H PSY

       UP

  • R55L PSY

       UP

  • R55S PSY

       UP

  • R55W PSY

       UP

  • R61A PSY

       UP

  • R61H PSY

       UP

  • R61L PSY

       UP

  • R61S PSY

       UP

  • R61W PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGSG7","label":"Tivoli Storage Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"55A","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
27 May 2009