IBM Support

PM71126: PATH ERROR CAUSED FREEZE ONLY APPLIED TO ONE LSS-LSS MM SESSION PPRC PAIRS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A path error caused the affected LSS00 to LSS00 Metro Mirror ppr
    c pair got suspended. However, TPC-R did not suspend other pairs
     in the same MM session. The logs indicated there is an
    IndexOutOfBoundsException at that time which contributed to this
     not handling the suspension of other pairs correctly.
    

Local fix

Problem summary

  • A suspend event could be initially received on
    a "Defined" session that has copysets added. The suspend event
    
    from the LSS would be caught and set a flag on the suspend
    marker. Since the session is in a defined state it does not do
    anything with the event. However this will cause a mismatch with
    the suspend
    marker and the event listener. On subsequent events this
    mismatch will cause some of the LSS to
    LSS pairings to not receive the suspend event from the hardware.
    

Problem conclusion

  • Sessions in the defined state now have the marker initialized
    prior to the start command. This will ensure that the
    suspend marker and event listener are in synch.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM71126

  • Reported component name

    TPC FOR REPL Z/

  • Reported component ID

    5608TRMZ0

  • Reported release

    41B

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-08-17

  • Closed date

    2012-08-22

  • Last modified date

    2012-08-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TPC FOR REPL Z/

  • Fixed component ID

    5608TRMZ0

Applicable component levels

  • R42B PSY

       UP

  • R51B PSY

       UP

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSMN28","label":"Tivoli Storage Productivity Center for Replication"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"41B"}]

Document Information

Modified date:
17 November 2021