IBM Support

PI97158: Provide a fallback message if the intended message is unavailable due to missing message table maintenance

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • When compiler generated code or the run-time need to issue a
    COBOL run-time message (IGZxxxxs), and the message is not
    available due to missing message table maintenance, an
    equivalent severity level generic message will be produced. That
    message will contain the message id and all the inserts in
    sequence that would otherwise have been issued.
    
    This avoids producing the serious level and otherwise not very
    informative CEE0454S message.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL V5+ who want to    *
    *                 deploy executable compiled with a compiler   *
    *                 version that make use of new/update COBOL    *
    *                 RTE (IGZ) messages, on a system that may be  *
    *                 missing the PTFs that contains the           *
    *                 new/updated COBOL RTE messages.              *
    *                                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: CEE3487S is issued during execution     *
    *                      when the program/runtime attempt to     *
    *                      issue a message that's not available    *
    *                      in the message module, due to the PTFs  *
    *                      with the updated to the module hasn't   *
    *                      been applied.                           *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    *                                                              *
    ****************************************************************
    When a message being issued is not available in the message
    module on the execution environment, an generic message of the
    same severity would be issued, together with the message number
    that's being issued and any message insert are printed in
    order.  The user can use the runtime message documentation to
    understand the reason of the messages.  This provided a reduced
    user experience with COBOL runtime message, but reduce the
    dependence of deployment of LE Runtime PTFs.  When the updated
    message module's PTF is installed, the message(s) issued would
    proceed normally.
    
    FIXCAT keyword: COB0501T/K  COB0502T/K  COB0601T/K  COB0602T/K
    

Problem conclusion

Temporary fix

Comments

  • The new feature is to address the user requirement of reducing
    the scheduling dependence of updated compiler generated
    executables to LE COBOL Runtime PTFs on deployment system(s).
    

APAR Information

  • APAR number

    PI97158

  • Reported component name

    LE ENT COBOL LI

  • Reported component ID

    568819812

  • Reported release

    790

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-04-24

  • Closed date

    2018-05-22

  • Last modified date

    2018-06-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PI97716 UI56042 UI56043

Modules/Macros

  • IGZCEV4  IGZLLIBV IGZXAPI  IGZXCDA  IGZXDMR
    IGZXD24  IGZXLPIO IGZXLPKA IGZXLPKB IGZXLPKC IGZXLPKD IGZXLPKE
    IGZXLPKF IGZXLPKG IGZXPK2
    

Fix information

  • Fixed component name

    LE ENT COBOL LI

  • Fixed component ID

    568819812

Applicable component levels

  • R7A0 PSY UI56042

       UP18/06/01 P F805

  • R790 PSY UI56043

       UP18/06/01 P F805

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCVR7X","label":"Runtime"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]

Document Information

Modified date: