A fix is available
APAR status
Closed as program error.
Error description
Continuation of APAR PI93046 for COBOL LE 2.2 Run-time fix.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Continuation of APAR PI93046 for COBOL * * LE 2.2 run-time. * * * * Enterprise COBOL V5+ users using Debug Tool * * under CICS with CBLPSHPOP(OFF) runtime * * option in effect. * * * **************************************************************** * PROBLEM DESCRIPTION: Debug Tool does not start: After * * relinking the bootstrap routines * * IGZXBST1, IGZXBST2, or IGZXBST3 * * provided by APAR PI85875, Debug Tool * * may fail to start a debugging session * * under CICS when the LE runtime option * * CBLPSHPOP(OFF) is in effect. * * * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * * * **************************************************************** APAR PI85875 improved dynamic call performance under CICS, by reducing the path length required to start a called program under CICS when CBLPSHPOP(OFF) is in effect. This also inadvertently disabled debugging with Debug Tool in some instances, for example, when a DTCN debug profile is setup to start a debugging session when a specific COBOL program is entered.
Problem conclusion
The bootstrap routines have been corrected to allow for debugging with Debug Tool under CICS with CBLPSHPOP(OFF).
Temporary fix
Comments
APAR Information
APAR number
PI95675
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
7A0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-03-23
Closed date
2018-03-23
Last modified date
2018-04-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI54726
Modules/Macros
IGZXBST IGZXBST1 IGZXBST2 IGZXBST3
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
R7A0 PSY UI54726
UP18/03/29 P F803
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCVR7X","label":"Runtime"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]
Document Information
Modified date: