A fix is available
APAR status
Closed as program error.
Error description
COBOL V5+ program performing a SORT is statically linked with a pre-V5 COBOL program. The executable program object is linked as AMODE(24) and RMODE(24). Exception in IGZEINI on a load instruction occurs on the call to the pre-V5 COBOL program. The exception occurs as psw is in 24 bit mode, attempting to address an 31 bit address. Problem occurs after applying the ptf for PI69070.
Local fix
Back off ptf for PI69070
Problem summary
**************************************************************** * USERS AFFECTED: Enterprise COBOL users running both COBOL * * V5+ and pre-V5 programs under AMODE 24, and * * SORT statement is used in the COBOL V5+ * * program. * * * **************************************************************** * PROBLEM DESCRIPTION: Runtime ABEND ABEND0C4 in IGZEINI. * * * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * * * **************************************************************** If the COBOL V5+ program uses SORT with INPUT or OUTPUT PROCEDURE, and pre-COBOL V5 program is called from within the INPUT/OUTPUT PROCEDURE, and the program is running in AMODE 24, the COBOL runtime mistakenly allocates a control block above the line. This causes abend ABEND0C4 when the control block is accessed. FIXCAT keyword: COB0501T/K COB0502T/K COB0601T/K
Problem conclusion
The logic in the COBOL runtime has been corrected to work properly for this scenario.
Temporary fix
Comments
APAR Information
APAR number
PI73815
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
790
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-12-14
Closed date
2017-01-20
Last modified date
2017-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI44109 UI44110
Modules/Macros
IGZCEV4 IGZLLIBV IGZXAPI IGZXDMR IGZXD24 IGZXLPIO IGZXLPKA IGZXLPKB IGZXLPKC IGZXLPKD IGZXLPKE IGZXLPKF IGZXLPKG IGZXPK2
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCVR7X","label":"Runtime"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]
Document Information
Modified date: