IBM Support

PI39496: 0C4 PROTECTION EXCEPTION IN CCNETBY MODULE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • An 0C4 protection exception is encountered in the CCNETBY module
    of the compiler.  The issue might be triggered by using the
    compiler TEMPLATEREGISTRY option.  The traceback appears similar
    to:
    
    
    
    Traceback:
    DSA Entry E Offset Statement Load Mod Program Unit Service
    Status
    
    1 CEEHDSP            +0000447E       CEEPLPKA CEEHDSP
      UI19380  Call
    
    2 CEEHRNUH           +00000096       CEEPLPKA CEEHRNUH
      HLE7780  Call
    
    3 getstackoffset_390 +00000184  233  CCNETBY
               Exception
    
    4 initildptr(int&,int&,int&,int&,int&,int&,int&,int&,int&,
                         +000000B0  454  CCNETBY
               Call
    
    ...
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: zOS C/C++ compiler users compiling with      *
    *                 TEMPLATEREGISTRY.                            *
    ****************************************************************
    * PROBLEM DESCRIPTION: An isolated parameter from a discarded  *
    *                      function incurs '0C4 protection         *
    *                      exception' in fap.                      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Apply provided service.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI39496

  • Reported component name

    C/C++ FOR MVS

  • Reported component ID

    56551210A

  • Reported release

    780

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-04-21

  • Closed date

    2015-07-03

  • Last modified date

    2016-06-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI29126 PI46356 PI46607 PI50495

Modules/Macros

  •    CCNECICS CCNECWI  CCNEDSCT CCNEDWRT CCNED1D0
    CCNEFILT CCNEHIFC CCNEMDEP CCNEOPTP CCNEP    CCNEPP   CCNETBY
    CCNMSGE  CCNMSGT
    

Fix information

  • Fixed component name

    C/C++ FOR MVS

  • Fixed component ID

    56551210A

Applicable component levels

  • R780 PSY UI29126

       UP15/07/22 P F507

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"780","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSQKCWV","label":"IBM C\/C++ for MVS\/ESA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"780","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: