A fix is available
APAR status
Closed as program error.
Error description
Exception occurs when mixing Enterprise COBOL V5 programs with Enterprise COBOL programs compiled with versions prior to V5. Problem occurs when executing an ACCEPT verb. Failing instruction is OI (9610 8011) due to an invalid address in gpr8.
Local fix
Problem does not occur when all programs are compiled with Enterprise COBOL V4.
Problem summary
**************************************************************** * USERS AFFECTED: Enterprise COBOL V5 users compiling * * and running programs that have ACCEPT from * * SYSIN, and run in address space where other * * COBOL programs compiled with earlier * * (pre-V5) COBOL programs that also * * use ACCEPT from SYSIN. * * * **************************************************************** * PROBLEM DESCRIPTION: ABEND 0C4 in IGZEINP when a V5 COBOL * * Program try to do an ACCEPT at * * End-of-data. * * * **************************************************************** * RECOMMENDATION: * **************************************************************** The routine that handle End-of-data in pre V5 COBOL Runtime for ACCEPT form SYSIN is not getting the expected control block when it receive control.
Problem conclusion
Apply provided service. The routine that handle End-of-data when ACCEPT form SYSIN is improved to handle the mixed (v5 and pre V5) scenario. FIXCAT keyword: COB0501T/K COB0502T/K
Temporary fix
Comments
APAR Information
APAR number
PI39312
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
790
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-04-16
Closed date
2015-05-13
Last modified date
2015-06-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI27688 UI27689
Modules/Macros
IGZCEV4 IGZLLIBV IGZXAPI IGZXDMR IGZXD24 IGZXLPIO IGZXLPKA IGZXLPKB IGZXLPKC IGZXLPKD IGZXLPKE IGZXLPKF IGZXLPKG IGZXPK2
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCVR7X","label":"Runtime"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
14 December 2020