IBM Support

PI25087: (COB V5.1) FILE MERGE RESULTS IN ABEND U4083 IN CEEPLPKA WHEN INPUT FILES BEING MERGED ARE EMPTY PLUS RENT/NORENT MIXTURE 0C4

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • (COB V5.1) This APAR addresses 2 issues:
    
    1) A file MERGE results in abend U4083 in CEEPLPKA when
    the input files being merged are empty.
    
    The COB V5.1 runtime will be modified to handle empty files as
    input to the MERGE statement.
    
    2) An abend0C4 may occur when a mixture of RENT & NORENT
    programs are linked together.
    
    For example:
    Program Y is compiled as NORENT.
    Program Y statically calls program Z which is compile as RENT.
    Therefore, program Z is linked into the program Y module.
    If the NORENT program Y is the main entry point, then an
    abend0C4 may occur.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: COBOL V5 programs using MERGE statement.     *
    *                 Applications containing both RENT and NORENT *
    *                 COBOL 5.1 programs statically linked into a  *
    *                 program object.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. The COBOL library routine reads the  *
    *                      first record of the input files as part *
    *                      of the initialization for the merging   *
    *                      process. The merge logic later on       *
    *                      wrongly assumes that at least one input *
    *                      record area is valid, which causes an   *
    *                      abend if the files are empty.           *
    *                      2. When a program object containing a   *
    *                      mix of COBOL V5.1 programs compiled     *
    *                      with the RENT and NORENT option, and    *
    *                      the primary entry point of the program  *
    *                      object is COBOL V5.1. NORENT, the       *
    *                      WORKING-STORAGE section for the RENT    *
    *                      program is not initialized correctly.   *
    *                      The program may get an 0C4 abend.       *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Apply provided service.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI25087

  • Reported component name

    LE ENT COBOL LI

  • Reported component ID

    568819812

  • Reported release

    780

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-09-03

  • Closed date

    2014-09-22

  • Last modified date

    2014-10-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGZXLPKA
    

Fix information

  • Fixed component name

    LE ENT COBOL LI

  • Fixed component ID

    568819812

Applicable component levels

  • R780 PSY UI21657

       UP14/09/30 P F409

  • R790 PSY UI21658

       UP14/09/30 P F409

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCVR7X","label":"Runtime"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
14 December 2020