A fix is available
APAR status
Closed as program error.
Error description
(COB V5.1) A COB V5.1 dynamic call to a COB II RES program fails with an abend0C4 under CICS. It does not matter which version of the bootstrap module is linked in. If SCEELKED((IGZEBST) is linked in or if COB2LIB(IGZEBST) is linked in, they both will fail with an abend0C4. If COB2CICS(IGZEBST) is linked in, the COB V5.1 dynamic call to COB II program will fail with an abend0C1. COB2CICS(IGZEBST) is an alias for COB2CICS(IGZ9BST). The problem only manifests itself when CICS is involved. Batch does not encounter this problem.
Local fix
Compile the COBOL II program under a supported version of Enterprise COBOL.
Problem summary
**************************************************************** * USERS AFFECTED: Users of COBOL V5.1 dynamic call to COBOL * * II RES program fails with S0C4 under CICS. * **************************************************************** * PROBLEM DESCRIPTION: COBOL V5.1 program dynamic call to * * COBOL II RES program under CICS gets * * ASRA/S0C4 in IGZEBST at +x'146'. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Apply provided service.
Temporary fix
Comments
APAR Information
APAR number
PI25079
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
780
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-09-03
Closed date
2014-09-25
Last modified date
2014-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI21657 UI21658
Modules/Macros
IGZCEV4 IGZLLIBV IGZXAPI IGZXDMR IGZXD24 IGZXLPIO IGZXLPKA IGZXLPKB IGZXLPKC IGZXPK2
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCVR7X","label":"Runtime"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
14 December 2020