A fix is available
APAR status
Closed as program error.
Error description
COBOL Version 5 program is entered in initial state when subsequently invoked from COBOL V5 program. This only occurs after 1st being invoked by a COBOL Version 4 program. The Version 4 program is compiled with DLL, EXPORTALL option along with the DYNAM=DLL on the bind step. PI10522 corrected the problem in a batch program. This APAR will address the problem under CICS.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Enterprise COBOL V5.1 users running CICS * * transactions that inter-operate with * * programs compiled with pre-V5.1 compilers. * **************************************************************** * PROBLEM DESCRIPTION: When a load module is first called by * * a pre-V5.1 COBOL program, then * * subsequently by a V5.1 program in CICS, * * the internal load module list * * maintained by the COBOL runtime may * * be updated unnecessarily, causing some * * V5.1 programs that have previously been * * run to loose their state information. * * This results in a new working storage * * section to be allocated each time the * * program is re-entered again. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Apply provided service.
Temporary fix
Comments
APAR Information
APAR number
PI16619
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
780
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-04-23
Closed date
2014-05-05
Last modified date
2014-06-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI17669 UI17670
Modules/Macros
IGZCEV4 IGZLLIBV IGZXAPI IGZXDMR IGZXD24 IGZXLPIO IGZXLPKA IGZXLPKB IGZXLPKC IGZXPK2
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.