PI07451: DUPLICATE OFFSETS IN Z/OS C ASSEMBLER SECTION

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • In the assembler section of a C listing, some of the offsets
    are duplicated when they follow the "END OF LITERALS" section
    without any comments and if the C file was compiled with option
    GONUMBER.
    
    EXAMPLE:
    
    0018C0                    End of Literals
    
    0018C00018C0
    
    0018C0  47F0  300C        003480 |        B        @225L2223
    0018C4                    003480 |        @225L2222DS       0H
    0018C4  5800  D0B8        003480 |     L     r0,dest_length(,r
    
    
    Note the offset 0018C0 and  0018C00018C0
    

Local fix

  • Use option NOGONUMBER.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: z/OS V1R13 C/C++ users with very large       *
    *                 function bodies compiling with NOXPLINK      *
    *                 LIST and GONUMBER options.                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: The "Start of Code Chunk #" header is   *
    *                      missing in pseudo-assembly listing.     *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Apply provided service.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI07451

  • Reported component name

    C/C++ FOR MVS

  • Reported component ID

    56551210A

  • Reported release

    790

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-12-04

  • Closed date

    2013-12-05

  • Last modified date

    2016-05-06

  • APAR is sysrouted FROM one or more of the following:

    PM98815

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    CCNETBY
    

Fix information

  • Fixed component name

    C/C++ FOR MVS

  • Fixed component ID

    56551210A

Applicable component levels

  • R790 PSY UI13286

       UP14/01/14 P F401

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"790","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSQKCWV","label":"IBM C\/C++ for MVS\/ESA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"790","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: