A fix is available
APAR status
Closed as program error.
Error description
S0C4 IGZXPRS1 offset X'3C0' using incorrect WSA address
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V5 or later * * releases running programs which call, by * * procedure pointer, the alternate entry * * point of another COBOL V5 or later program. * **************************************************************** * PROBLEM DESCRIPTION: The caller program terminates with 0C4 * * ABEND, or produces incorrect outputs * * in subsequent static calls due to * * storage corruption. * **************************************************************** * RECOMMENDATION: Install the provided PTF. * **************************************************************** Due to incorrect handling of writable static area (the address in CRENT field in LE CAA + 0x1F4) in the COBOL Runtime, V5+ programs might terminate with 0C4 ABEND, or produce incorrect outputs with later static calls (after the current procedure pointer call), when all of the following conditions are met prior to the call: - COBOL V5+ program is calling another COBOL V5+ using procedure pointer - The caller and callee are in different program objects - The callee is entered through an alternate entry point - The callee has been initialized; that is, it has been called before. Note: V5+ means V5 or later releases COB0501T/K COB0502T/K COB0601T/K COB0602T/K COB0603T/K
Problem conclusion
The handing of writable static area in COBOL Runtime is corrected.
Temporary fix
Comments
APAR Information
APAR number
PH23903
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
7C0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-03-31
Closed date
2020-04-20
Last modified date
2020-05-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGZCEV4 IGZLLIBV IGZXAPI IGZXCDA IGZXD24 IGZXDMR IGZXLPIO IGZXLPKA IGZXLPKB IGZXLPKC IGZXLPKD IGZXLPKE IGZXLPKF IGZXLPKG IGZXPK2
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
R7A0 PSY UI69091
UP20/04/25 P F004
R7B0 PSY UI69093
UP20/04/25 P F004
R7C0 PSY UI69094
UP20/04/25 P F004
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCVR7X","label":"Runtime"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]
Document Information
Modified date: