A fix is available
APAR status
Closed as program error.
Error description
In a multi-language application, mixing COBOL and PL/I, there was an invalid COBOL control block (GPCB).
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: User of Enterprise COBOL V5+, running COBOL * * programs that contain FILE Definitions * * (FD),and are called via inter-language * * call(ILC) by program written in another * * LE high level language (for example, PL/I). * **************************************************************** * PROBLEM DESCRIPTION: ABEND with error message: IGZ0099C * * Internal error GPCB-IPCB in module * * IGZ@PRC, during termination phase of * * the program execution. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** At program termination, the COBOL runtime is releasing all files and related resources that are acquired for the COBOL program. In the ILC case, termination processing is incorrectly done a second time, which results in the IGZ0099C error message. COB0501T/K COB0502T/K COB0601T/K COB0602T/K COB0603T/K
Problem conclusion
The logic in program termination processing has been corrected.
Temporary fix
Comments
APAR Information
APAR number
PH22676
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
7C0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-02-26
Closed date
2020-03-25
Last modified date
2020-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGZCEV4 IGZLLIBV IGZXAPI IGZXCDA IGZXD24 IGZXDMR IGZXLPIO IGZXLPKA IGZXLPKB IGZXLPKC IGZXLPKD IGZXLPKE IGZXLPKF IGZXLPKG IGZXPK2
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
R7A0 PSY UI68610
UP20/04/01 P F003
R7B0 PSY UI68612
UP20/04/01 P F003
R7C0 PSY UI68614
UP20/04/01 P F003
Fix is available