A fix is available
APAR status
Closed as program error.
Error description
An abend 0C4 Pic 11 can occur after adding buffers to a data set opened in LSR Mode. z/OS 2.2 will attempt to add buffers to an LSR Pool if there are insufficient buffers. During this process after adding buffers VSAM will attempt to update the RPL feedback code to indicate to the caller that buffers were added. In the reported case VSAM had added buffers and was attempting to update the RPL feedback to indicate this. However the register used to point to the RPL had previously been used to point to storage to be freemained, so when VSAM attempted to update the RPL feedback code an abend 0C4 pic 11 occurred.
Local fix
Specify sufficient LSR buffers so that Dynamic Buffer Addition is not attempted.
Problem summary
**************************************************************** * USERS AFFECTED: ALL VSAM USERS WITH HDZ2220 PERFORMING * * DYNAMIC BUFFER ADDITION. * **************************************************************** * PROBLEM DESCRIPTION: AN ABEND0C4 OR 1 BYTE OVERLAY MAY OCCUR * * DURING DYNAMIC BUFFER ADDITION. * **************************************************************** * RECOMMENDATION: APPLY PTF. * **************************************************************** WHEN INSUFFICIENT BUFFERS EXIST IN A LSR POOL TO SATISFY A REQUEST DYNAMIC BUFFER ADDITION ADDS MORE BUFFERS TO THE POOL. A RPLERRCD IS SET TO INFORM THE CALLER DYNAMIC BUFFER ADDITION HAS OCCURRED. AN ABEND0C4 OR ONE WORD OVERLAY MAY OCCUR WHEN SETTING RPLERRCD AS THE POINTER TO THE RPL IS NOT PROPERLY SET.
Problem conclusion
MODULE IDA019RP IS CHANGED TO CORRECTLY POINT TO THE RPL WHEN SETTING RPLERRCD.
Temporary fix
Comments
APAR Information
APAR number
OA50436
Reported component name
DFSMS VSAM
Reported component ID
5695DF106
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-05-04
Closed date
2016-05-26
Last modified date
2016-07-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA81826
Modules/Macros
IDA019RP
Fix information
Fixed component name
DFSMS VSAM
Fixed component ID
5695DF106
Applicable component levels
R220 PSY UA81826
UP16/06/28 P F606
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: