Error description
For devices with FRU :00E2715, the EEH errors were logged at the time of system bringup/reboot
Local fix
Problem summary
For devices with FRU :00E2715, the EEH errors were logged at the time of system bringup/reboot
Problem conclusion
IOCTLs to driver are serialized with simple lock such that only one IOCTL is allowed at any given time.
Temporary fix
Comments
6100-08 - use AIX APAR IV70005 6100-09 - use AIX APAR IV69632 7100-02 - use AIX APAR IV70256 7100-03 - use AIX APAR IV69637
APAR Information
APAR number
IV69632
Reported component name
AIX 610 STD EDI
Reported component ID
5765G6200
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2015-02-18
Closed date
2015-02-18
Last modified date
2015-11-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX 610 STD EDI
Fixed component ID
5765G6200
Applicable component levels
R610 PSY U857401
UP15/11/20 I 1000
PTF to Fileset Mapping
U867499 devices.ethernet.shi.rte 6.1.9.45
U857401 devices.ethernet.shi.rte 6.1.9.100
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11Q","label":"AIX 6.1 HIPERS, APARs and Fixes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSMV87","label":"AIX 6.1 Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMVAX","label":"AIX Express Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSAUMY","label":"IBM AIX Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11Q","label":"AIX 6.1 HIPERS, APARs and Fixes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11R","label":"APARs - AIX 7.1 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]