IV59739: J2 SNAPSHOT MOUNT GIVES INCORRECT EFS ERROR MSG AND FAILS APPLIES TO AIX 6100-08

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The following snapshot mount command can result in
    following incorrect error:
    
    mount -v jfs2 -o snapshot /dev/<snap_lv> /<snap_mnt_pnt>
    
    The CLiC library (libclic.a) is not available. Install
    clic.rte and run
    'efsenable -a'.
    =================================================
    The check for the libclic.a is not necessary for a
    snapshot mount and
    should not be done. The problem causes access to
    incorrect data which if
    is a certain value can cause error message.  So this
    problem is only seen
    on some machines and not others.
    

Local fix

  • user could follow error directions and install Clic
    library
    as work around but I am not sure that works in every
    case.
    

Problem summary

  • The following snapshot mount command can result in
    following incorrect error:
    
    mount -v jfs2 -o snapshot /dev/<snap_lv> /<snap_mnt_pnt>
    
    The CLiC library (libclic.a) is not available. Install
    clic.rte and run
    'efsenable -a'.
    =================================================
    The check for the libclic.a is not necessary for a
    snapshot mount and
    should not be done. The problem causes access to
    incorrect data which if
    is a certain value can cause error message.  So this
    problem is only seen
    on some machines and not others.
    

Problem conclusion

  • Modified code to omit efs check for snapshot mounts.
    

Temporary fix

Comments

  • 6100-08 - use AIX APAR IV59739
    6100-09 - use AIX APAR IV60144
    6100-09 - use AIX APAR IV60144
    7100-02 - use AIX APAR IV64164
    7100-03 - use AIX APAR IV60149
    7100-04 - use AIX APAR IV60228
    

APAR Information

  • APAR number

    IV59739

  • Reported component name

    AIX 610 STD EDI

  • Reported component ID

    5765G6200

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2014-04-24

  • Closed date

    2014-04-30

  • Last modified date

    2016-05-10

Fix information

  • Fixed component name

    AIX 610 STD EDI

  • Fixed component ID

    5765G6200

Applicable component levels

  • R610 PSY U867317

       UP15/01/18 I 1000

PTF to Fileset Mapping

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLLZP","label":"AIX Standard Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSMV87","label":"AIX 6.1 Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMVAX","label":"AIX Express Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSAUMY","label":"IBM AIX Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11Q","label":"AIX 6.1 HIPERS, APARs and Fixes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11R","label":"APARs - AIX 7.1 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: