A fix is available
APAR status
Closed as program error.
Error description
since IV24259 ps -o time outputs are incorrect, they usually print all zero values.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * Systems running the 6100-08 Technology Levels with the * bos.rte.control fileset below the 6.1.8.15 level. **************************************************************** * PROBLEM DESCRIPTION: * The ps command reports incorrect time information. It usually * prints all zero values. For example: * * ps -eo "pid comm etime time pcpu" * * PID COMMAND ELAPSED TIME %CPU * 1 init 4-16:56:27 00:00:00 0.0 * 1769702 shlap64 4-16:55:50 00:00:00 0.0 * 2228382 syncd 4-16:55:16 00:00:18 0.0 * 2556066 errdemon 4-16:55:13 00:00:00 0.0 * 2883764 cimssys 4-16:54:29 00:00:00 0.0 **************************************************************** * RECOMMENDATION: * Install APAR IV32415. ****************************************************************
Problem conclusion
changed acess specifiers from 32-bit to 64-bit
Temporary fix
Comments
6100-08 - use AIX APAR IV32415 7100-02 - use AIX APAR IV34069
APAR Information
APAR number
IV32415
Reported component name
AIX 610 STD EDI
Reported component ID
5765G6200
Reported release
610
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Submitted date
2012-11-26
Closed date
2012-12-28
Last modified date
2013-11-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX 610 STD EDI
Fixed component ID
5765G6200
Applicable component levels
R610 PSY U855307
UP13/11/20 I 1000
PTF to Fileset Mapping
U855307 bos.rte.control 6.1.9.0
U851251 bos.rte.control 6.1.8.15
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSMV87","label":"AIX 6.1 Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMVAX","label":"AIX Express Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSAUMY","label":"IBM AIX Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11Q","label":"AIX 6.1 HIPERS, APARs and Fixes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
26 November 2013