IBM Support

IV32415: SINCE IV24259 PS -EO ETIME,TIME TIMES ARE INCORRECT. APPLIES TO AIX 6100-08

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • since IV24259 ps -o time outputs are incorrect, they
    usually
    print all zero values.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:
    * Systems running the 6100-08 Technology Levels with the
    * bos.rte.control fileset below the 6.1.8.15 level.
    ****************************************************************
    * PROBLEM DESCRIPTION:
    * The ps command reports incorrect time information.  It usually
    * prints all zero values. For example:
    *
    * ps -eo "pid comm etime time pcpu"
    *
    *     PID COMMAND      ELAPSED        TIME  %CPU
    *       1 init      4-16:56:27    00:00:00   0.0
    * 1769702 shlap64   4-16:55:50    00:00:00   0.0
    * 2228382 syncd     4-16:55:16    00:00:18   0.0
    * 2556066 errdemon  4-16:55:13    00:00:00   0.0
    * 2883764 cimssys   4-16:54:29    00:00:00   0.0
    ****************************************************************
    * RECOMMENDATION:
    * Install APAR IV32415.
    ****************************************************************
    

Problem conclusion

  • changed acess specifiers from 32-bit to 64-bit
    

Temporary fix

Comments

  • 6100-08 - use AIX APAR IV32415
    7100-02 - use AIX APAR IV34069
    

APAR Information

  • APAR number

    IV32415

  • Reported component name

    AIX 610 STD EDI

  • Reported component ID

    5765G6200

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Submitted date

    2012-11-26

  • Closed date

    2012-12-28

  • Last modified date

    2013-11-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    IV34069 IV34150 IV34216

Fix information

  • Fixed component name

    AIX 610 STD EDI

  • Fixed component ID

    5765G6200

Applicable component levels

  • R610 PSY U855307

       UP13/11/20 I 1000

PTF to Fileset Mapping

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSMV87","label":"AIX 6.1 Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMVAX","label":"AIX Express Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSAUMY","label":"IBM AIX Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11Q","label":"AIX 6.1 HIPERS, APARs and Fixes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"","label":""}}]