IV13753: COMPLETION EVENT NOT SENT FOR IOCP APPLIES TO AIX 6100-07

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The symptom from the customer's perspective is the
    GetMultipleCompletionStatus does not return a completion
    event even though the send has completed.
    

Local fix

Problem summary

  • An application which does a WriteFile() and then waits for the
    completion event may hang waiting for the completion event in
    GetMultipleCompletionStatus() or GetQueuedCompletionStatus()
    call, even though send is completed.
    

Problem conclusion

  • Changed the iocp code to properly send the completion event
    which used to be missed in certain circumstances.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV13753

  • Reported component name

    AIX 610 STD EDI

  • Reported component ID

    5765G6200

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2012-01-20

  • Closed date

    2012-02-17

  • Last modified date

    2013-02-27

  • APAR is sysrouted FROM one or more of the following:

    IV10828

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX 610 STD EDI

  • Fixed component ID

    5765G6200

Applicable component levels

  • R610 PSY U841072

       UP12/05/11 I 1000

PTF to Fileset Mapping

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSMV87","label":"AIX 6.1 Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMVAX","label":"AIX Express Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSAUMY","label":"IBM AIX Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11Q","label":"AIX 6.1 HIPERS, APARs and Fixes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"","label":""}}]