A fix is available
APAR status
Closed as program error.
Error description
During a node-by-node upgrade from PowerHA 6.1.0.0, 6.1.0.1, or 6.1.0.2 to a level of 6.1.0.3 or higher, the sync operation fails. "WARNING: Node <<node1>> does not match the configuration on active node: <<node2>> A snapshot for node <<node1>> was already created today, a new one will not be created Topsvcs is active, new instance num is <<#>> Adding any necessary HACMP entries to /etc/inittab and /etc/rc.net for IPAT on node <<node1>>. clconfig: Verification determined 1 error(s) occurred. Please correct any errors and retry. Cluster services will not start on node(s): <<node1>>" The /var/hacmp/log/autoverify.log also shows: "Failed to distribute HACMPtc ODMs to node <<node1>>."
Local fix
Perform smitty clstart operation twice on the node being upgraded.
Problem summary
During a node-by-node upgrade from PowerHA 6.1.0.0, 6.1.0.1, or 6.1.0.2 to a level of 6.1.0.3 or higher, the sync operation fails. The /var/hacmp/log/autoverify.log shows: "Failed to distribute HACMPtc ODMs to node <<node1>>."
Problem conclusion
Updated the README with upgrade instructions applicable only for PowerHA clusters running at 6.1.0.0, 6.1.0.1, or 6.1.0.2 levels. PTF(s) must be installed on all nodes at the same time, without intervening reboot, node restart, or verify & sync.
Temporary fix
Comments
APAR Information
APAR number
IV13682
Reported component name
POWERHA 6.1 BAS
Reported component ID
5765H2300
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2012-01-19
Closed date
2012-11-20
Last modified date
2013-01-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
POWERHA 6.1 BAS
Fixed component ID
5765H2300
Applicable component levels
R610 PSY U855568
UP13/01/24 I 1000
PTF to Fileset Mapping
U855568 cluster.es.server.rte 6.1.0.10
U855568 cluster.es.server.rte 6.1.0.10
U855568 cluster.es.server.rte 6.1.0.10
U855568 cluster.es.server.rte 6.1.0.10
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSXU4N","label":"PowerHA SystemMirror Enterprise Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU008","label":"Security"},"Product":{"code":"SGL4G4","label":"PowerHA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU008","label":"Security"},"Product":{"code":"SGL4G4","label":"PowerHA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"","label":""}}]