A fix is available
APAR status
Closed as program error.
Error description
With the introduction of V8 ONTAP firmware on the Netapp, if ALUA is enabled on the array, AIX PCM may wrongly direct I/O to NON-OPTIMIZED paths. This can be determined by observing I/O on the partner paths/ NON-OPTIMIZED paths.
Local fix
turn off ALUA on the array and use dotpaths to manage path priorties and or back level the version of ONTAP to version 7.xx
Problem summary
Even when ALUA is enabled, AIX PCM may send down IO thru non-optimized paths instead of optimized paths. It can be observed by monitoring IO on different paths.
Problem conclusion
The issue was the result of optimized port info getting wiped out due to interference of simultaneous probing of ALUA on different paths. Code in AIX PCM fixed so as to prevent such interference.
Temporary fix
Comments
APAR Information
APAR number
IV04295
Reported component name
AIX 5.3
Reported component ID
5765G0300
Reported release
530
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2011-08-03
Closed date
2011-08-03
Last modified date
2013-04-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX 5.3
Fixed component ID
5765G0300
Applicable component levels
R530 PSY U844638
UP11/10/10 I 1000
PTF to Fileset Mapping
U844638 devices.common.IBM.mpio.rte 5.3.12.5