IBM Support

IV04265: DIAGS MAY REPORT FALSE FAILURE ON GXT145 DUE TO EEH ERROR APPLIES TO AIX 5300-12

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When running diags on the GXT145 graphics adapter, an EEH error
    could occur and the diagnostic will report the GXT145 as failed
    when it may not have failed.
    

Local fix

Problem summary

  • When running diags on the GXT145 graphics adapter, an EEH error
    could occur and the diagnostic will report the GXT145 as failed
    when it may not have failed.
    

Problem conclusion

  • The software was changed to properly detect whether a byte,
    short, or long value was being read when the problem was first
    detected by the diagnostic.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV04265

  • Reported component name

    AIX 5.3

  • Reported component ID

    5765G0300

  • Reported release

    530

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2011-08-03

  • Closed date

    2011-08-03

  • Last modified date

    2013-04-16

Fix information

  • Fixed component name

    AIX 5.3

  • Fixed component ID

    5765G0300

Applicable component levels

  • R530 PSY U844635

       UP11/10/10 I 1000

PTF to Fileset Mapping

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11P","label":"APARs - AIX 5.3 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"530","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
16 April 2013