IBM Support

Fix readme for 5.0.0.1-IBM-IMA-IFIT29187

Fix Readme


Abstract

This readme describes the contents and fixes included in new interim fix 5.0.0.1-IBM-IMA-IFIT29187

Content

Interim Fix: 5.0.0.1-IBM-IMA-IFIT29187
Date: May 29, 2019
Build: 20190529-2149
IBM MessageSight 5.0.0.1 Cumulative interim fix

(Note: all MessageSight 5.x ifixes and fixpacks are cumulative.  In addition, because of the nature of the fix packaging for 5.0, any published fix can be used for the base install of MessageSight.  It is recommend to install the latest IFIX or FP as the initial install of the product.)

Fix Details

Component md5sum File
Bridge 8652a3adaa8ab4aca4e2b5852c78f1a3 5.0.0.1-IBM-IMA-IFIT29187-Bridge.tz
Server 4ebb1207880dc7f4bf7ba59dae0a235d 5.0.0.1-IBM-IMA-IFIT29187-Server.tz
WebUI 50a2aff135b74a39d0f30eab0a99ac33 5.0.0.1-IBM-IMA-IFIT29187-WebUI.tz

APARs fixed in this build

APAR Description
IT28640 Fix server shutdown rc=15
IT29187 Update Java impacted by CVEs: CVE-2019-2698, CVE-2019-2697, CVE-2019-2602, CVE-2019-10245
IT29189 Update jQuery impacted by CVE-2019-11368
IT29295 Fix webui shutdown rc=143

Fix Instructions:

Before you install:

We strongly recommend performing a backup before upgrading the product software:

Backup and restore instructions

1. Preparing to install the fix:

Prepare the IBM IoT MessageGateway .tz files for installation.  The preparation steps for installing MessageGateway as an update or for the first time are the same.  For more information, see Preparing the IBM IoT MessageGateway .tz packages for installation .

These instructions will focus on providing instructions for updating MessageSight.  See the following instructions for installing MessageGateway for the first time:

Installing IBM IoT MessageGateway

2. Installing the fix:

A. RPM: In an environment where MessageGateway is installed with rpm:

I. Updating the MessageGateway package if Server is installed:

      cd imaserver

      sudo  yum -y --nogpgcheck update IBMWIoTPMessageGatewayServer*.rpm

      systemctl start IBMIoTMessageSightServer

II. Updating the MessageSight WebUI package if the WebUI is installed:

      cd imawebui

      sudo yum -y --nogpgcheck update IBMWIoTPMessageGatewayWebUI*.rpm

      systemctl start IBMIoTMessageSightWebUI

II. Updating the MessageSight Bridge package if the Bridge is installed:

      cd imabridge

      sudo  yum -y --nogpgcheck update IBMWIoTPMessageGatewayBridge*.rpm

      systemctl start IBMIoTMessageSightBridge

NOTE: these packages can also be installed using: rpm -Uvh IBMWIoTPMessageGateway*.rpm. However, you must never update using:

yum install IBMWIoTPMessageGatewayServer*.rpm

or uninstall and reinstall with rpm or yum (if you wish to preserve your existing data), since this will remove all of your data and config under /var/messagesight.

B. Docker: Installing the fix in an environment where IBMWIoTPMessageGateway is running in docker:

I. Build the IBM IoT MessageSight Docker image.

Build the IBM IoT MessageGateway server image by issuing the following command:

cd imaserver

mv *.rpm imaserver.rpm

docker build --force-rm=true -t <server_image_name>:<fix_version>.<build> .

Eg:

docker build --force-rm=true -t imaserver:5.0.0.0.20190518-0249 .

II. Build the IBM IoT MessageGateway Web UI image by issuing the following command:

cd imawebui

mv *.rpm imawebui.rpm

docker build --force-rm=true -t <webui_image_name>:<fix_version>.<build> .

Eg:

docker build --force-rm=true -t imawebui:5.0.0.0.20190518-0249 .

III. Build the IBM IoT MessageGateway Bridge image by issuing the following command:

cd imabridge

mv *.rpm imabridge.rpm

docker build --force-rm=true -t <bridge_image_name>:<fix_version>.<build> .

Eg:

docker build --force-rm=true -t imabridge:5.0.0.0.20190518-0249 .

III.  Stop the existing containers.

Stop the server container by issuing the following command:

docker stop <server_container_name>

where <server_container_name> is the name of the container in which the IBM IoT MessageGateway server is running. For example,

docker stop imaserver

Stop the Web UI container by issuing the following command:

docker stop <webui_container_name>

where <webui_container_name> is the name of the container in which the IBM IoT MessageGateway Web UI is running. For example,

docker stop imawebui

Stop the Bridge container by issuing the following command:

docker stop <bridge_container_name>

where <bridge_container_name> is the name of the container in which the IBM IoT MessageGateway Bridge is running. For example,

docker stop imabridge

IV. Remove the containers.

Remove the server container by issuing the following command:

docker rm <server_container_name>

where <server_container_name> is the name of the container in which the IBM IoT MessageGateway server was running. For example,

docker rm imaserver

Remove the Web UI container by issuing the following command:

docker rm <webui_container_name>

where <webui_container_name> is the name of the container in which the IBM IoT MessageGateway Web UI was running. For example,

docker rm imawebui

Remove the Bridge container by issuing the following command:

docker rm <bridge_container_name>

where <bridge_container_name> is the name of the container in which the IBM IoT MessageGateway Bridge was running. For example,

docker rm imabridge

V.  Remove the old MessageGateway images (optional)

This step is only required if you are not tagging MessageGateway docker images with version specific tags.  For example, if you build a MessageGateway docker image like this:

docker build --force-rm=true -t imaserver:5.0 .

for every version of MessageGateway, then you need to remove the previous image by issuing the following command(s), before building the update image:

docker rmi -f $(docker ps | grep imaserver | awk '{print $3}')

Remove the IBM IoT MessageGateway Web UI image by issuing the following command:

docker rmi -f $(docker ps | grep imawebui | awk '{print $3}')

Remove the IBM IoT MessageGateway Bridge image by issuing the following command:

docker rmi -f $(docker ps | grep imabridge | awk '{print $3}')

If, however, you tag each MessageGateway image with a build specific version, eg:

docker build --force-rm=true -t imaserver:<fix_version>.<build> .

then this step is not required.

VI.  Start the new containers.

Use the same Docker run command that you had used for previous incarnations of the MessageGateway containers.

Here's the general syntax for how to start the IBM IoT MessageGateway server container:

docker run --cap-add SYS_ADMIN --net=host -P -it --name=<server_container_name> -env-file=IBMIoTMessageGatewayServer-docker.env -m <memory> -v <local_data_directory>:/var/messagesight -v <local_temp_directory>:/var/tmp -d <server_image_name>:<fix_version>.<build>

A more concrete example:

docker run --cap-add SYS_ADMIN --net=host -P -it --name=imaserver -env-file=IBMIoTMessageGatewayServer-docker.env -m 64G -v /data/messagesight:/var/messagesight -v /mnt/tmp:/var/tmp -d imaserver:5.0.0.0.20190422-2029

To start the IBM IoT MessageSight Web UI container:

docker run --cap-add SYS_ADMIN --net=host -P -it --name=<webui_container_name> --env-file=IBMIoTMessageSightServer-docker.env -m <memory> -v <local_data_directory>:/var/messagesight -v <local_temp_directory>:/var/tmp -d <webui_image_name>:<fix_version>.<build>

A more concrete example:

docker run --cap-add SYS_ADMIN --net=host -P -it --name=imawebui --env-file=IBMIoTMessageGatewayServer-docker.env -m 2G -v /data/messagesight:/var/messagesight -v /mnt/tmp:/var/tmp -d imawebui:5.0.0.0.20190422-2029

To start the IBM IoT MessageSight Bridge container:

docker run --cap-add SYS_ADMIN --net=host -P -it --name=<bridge_container_name> --env-file=IBMIoTMessageGatewayBridge-docker.env -m <memory> -v <local_data_directory>:/var/messagesight -v <local_temp_directory>:/var/tmp -d <bridge_image_name>:<fix_version>.<build>

A more concrete example:

docker run --net=host -P -it --name=imabridge --env-file=IBMIoTMessageGatewayBridge-docker.env -m 2G -v /data/messagesight:/var/messagesight -v /mnt/tmp:/var/tmp -d imabridge:5.0.0.0.20190422-2029

3. Verifying the installation:

If this is your initial install of the product see Configuring the licensed usage for IBM IoT MessageGateway and accepting the license by using REST Administration APIs for accepting the product license .

If this is an update, then you can verify the status of the server see Viewing the status of an IBM IoT MessageGateway server and services by using REST Administration APIs .

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSWMAJ","label":"IBM IoT MessageSight"},"Component":"","Platform":[],"Version":"All Versions","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
04 June 2019

UID

ibm10886213