PK68282: SINGLE PORTLET ACTION NOT EXECUTED AFTER SESSION TIMEOUT.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • After a session timeout occurred, there can be the case that the
    portlet action of one URL might not be executed.
    Instead of executing the portlet action, only the rendering
    method of the portlet is executed.
    

Local fix

  • At the point of time when the session timeout occurs, the Action
    ID counter is reset, but the previously executed URL is saved
    with an action ID that was computed before the reset took place.
    Without the fix, the case can occur that this action ID is
    assigned with an action URL, again. Then, this URL would not
    execute the portlet action correctly, because the system detects
    that the action with this ID has already executed. The fix
    ensures that the action ID is not reset to a static value, but
    reset to a random initial value, so that it is almost impossible
    that duplicate action IDs are ever used.
    

Problem summary

  • After a session timeout occurred, there can be the case that the
    portlet action of one URL might not be executed. Instead of
    executing the portlet action, only the rendering method of the
    portlet is executed.
    

Problem conclusion

  • At the point of time when the session timeout occurs, the Action
    ID counter is reset, but the previously executed URL is saved
    with an action ID that was computed before the reset took place.
    Without the fix, the case can occur that this action ID is
    assigned with an action URL, again. Then, this URL would not
    execute the portlet action correctly, because the system detects
    that the action with this ID has already executed. The fix
    ensures that the action ID is not reset to a static value, but
    reset to a random initial value, so that it is almost impossible
    that duplicate action IDs are ever used.
    
    Failing Module(s):
       Engine: URL Generation
    
    Affected Users:
       all users
    
    Version Information:
        Portal Version(s): 6.0.1.3
         Pre-Requisite(s):
          Co-Requisite(s): ---
    
        Portal Version(s): 6.1.0.0
         Pre-Requisite(s):
          Co-Requisite(s): ---
    
    Platform Specific:
       This fix applies to all platforms.
    
    A fix is available from Fix Central:
    
    http://www.ibm.com/eserver/support/fixes/fixcentral/swgquickorde
    r?apar=PK68282&productid=WebSphere%20Portal&brandid=5
    
    You may need to type or paste the complete address into your Web
    browser.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK68282

  • Reported component name

    WEBSPHERE PORTA

  • Reported component ID

    5724E7600

  • Reported release

    60G

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-06-30

  • Closed date

    2008-08-18

  • Last modified date

    2008-08-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBSPHERE PORTA

  • Fixed component ID

    5724E7600

Applicable component levels

  • R60G PSY

       UP

  • R610 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSHRKX","label":"WebSphere Portal"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.1.3","Line of Business":{"code":"LOB31","label":"WCE Watson Marketing and Commerce"}}]

Document Information

Modified date:
21 December 2021