  • Problem Description:
    When the customer specify the "NewLogBasedOn=mtime" variable in
    the tecad_logfile.conf, "chmod nnn file" causes to fire the
    event.
    Failing TEC Component(s): adapter
    
    Customer/Recreate Environment: HP-UX 11
    
    Database:                 N/A
    
    TME Framework:            4.1.1 + TMF-0070
    
    Install Method:           Upgrade
    
    TEC Server:               TEC 3.9.0+FP05
    
    Tec Gateway:              TEC 3.9.0+FP05
    
    Tec UI Server:            TEC 3.9.0+FP05
    
    Websphere server:         N/A
    
    Tec Console:              N/A
    
    Endpoints:                41138
    
    Adapter:                  TEC 3.9.0+FP05
    
    TMR/TEC same machine:     YES
    
    Affected Locale(s):       N/A
    
    Collected Information :   none
    
    (Placed in l2l3 folder - /tivoli/tec/l2l3/APARs/)
    
    Last Known Good Level:    N/A
    
    L3 Acknowledged:          Yes/No (LB)
    
    Recreate Steps/Correct information:   (Defect)
    I tested this behavior on my AIX environment.
    I performed the following operation.
    1. Edit the ACP profile
    2. Specify the "ctime" to the "NewLogBasedOn" parameter and save
    it.
    3. Distribute the profile to the endpoint.
    4. perform the following operation to check
      - touch file
      - chmod NNN file
      - chgrp group file
    Continue from step-1. changing the "NewLogBasedOn" parameter to
    "mtime"
    and "cmtime".
    
    The result is as follows.
    The event was sent on all of cases.
    ------------------------------------------------------
    NewLogBasedOn | touch file | chmod      | chgrp      |
    ------------------------------------------------------
    mtime         | sent event | sent event | sent event |
    ------------------------------------------------------
    
    Local fix:                none
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of TEC EEIF adapters on Unix
    ****************************************************************
    * PROBLEM DESCRIPTION: When an adapter config file contains the
    * following keyword and value: NewLogBasedOn=mtime, the adapter
    * will still treat the log as new when the size does not change,
    * but the ctime does change.
    ****************************************************************
    * RECOMMENDATION: Apply maintenance vehicle listed below
    ****************************************************************
    This functionality was not implemented on Unix- on creation time
    was tracked, etc.
    

Problem conclusion

  • ctime was the only attribute preserved in the structures that
    tracked each logsource. Added mtime for Unix and associated
    logic to update, check, etc. Now the Unix adapters behave as the
    Win adapters in that mtime, ctime and cmtime are all valid
    checked values as per the existing doc on these values.
    
    The fix for this APAR is contained in the
    following maintenance packages:
    
    | LA Fix | 3.9.0.8-TIV-TEC-LA0091
    
    Note: Search IBM Technical Support web site for maintenance
    package availability.
    

Temporary fix

  • N/A
    

Comments

APAR Information

  • APAR number

    IZ24175

  • Reported component name

    TIVOLI ENT.CONS

  • Reported component ID

    5698TEC00

  • Reported release

    390

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-06-11

  • Closed date

    2008-07-09

  • Last modified date

    2008-07-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TIVOLI ENT.CONS

  • Fixed component ID

    5698TEC00

Applicable component levels

  • R390 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSGMKC","label":"Tivoli Enterprise Console"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"390","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
09 July 2008