IBM Support

IY92879: MESSAGE TEXT FOR ITM_* EVENTS IS "()="

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Problem is as follows, ITM 6.1 uses DM 3.7 classes to send TEC
    events.
    In DM 3.7 the ruleset sentry.rls is included and used. It
    contains the following line which is executed for all events of
    the DM 3.7 class:
    .
    set_event_message(_event, '%s (%s) = %s %s', [_monitor,
    _probe_arg, _value, _units])
    .
    The values for _monitor, _probe_arg, _value and _units are taken
    from the homonymous slots. These slots are set if DM 3.7 sends a
    event, but are not set if ITM 6.1 sends a TEC event. Here the
    msg slot is already set correctly. After this it gets changed to
    " () =" which is not quite helpful. The problem is for DM 3.7
    you have to use this ruleset to get a proper msg slot.
    So ITM 6.1 either fill these slots or should use it's own
    classes.
    

Local fix

Problem summary

  • When DM 3.7 events were sent to TEC via ITM 6.1, the msg slot in
    the event gets set to " () =".
    

Problem conclusion

  • Change the sentry.rls file to check for a source of ITM
    before changing the msg slot.
    
    The fix for this APAR is contained in the following maintenance
    packages:
      | fix pack | 3.9.0-TIV-TEC-FP0007
    

Temporary fix

Comments

APAR Information

  • APAR number

    IY92879

  • Reported component name

    TEMA

  • Reported component ID

    5724C04TE

  • Reported release

    390

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-01-11

  • Closed date

    2007-10-05

  • Last modified date

    2007-10-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TIVOLI ENT.CONS

  • Fixed component ID

    5698TEC00

Applicable component levels

  • R390 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSGMKC","label":"Tivoli Enterprise Console"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"390","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: