A fix is available
APAR status
Closed as program error.
Error description
Problem is as follows, ITM 6.1 uses DM 3.7 classes to send TEC events. In DM 3.7 the ruleset sentry.rls is included and used. It contains the following line which is executed for all events of the DM 3.7 class: . set_event_message(_event, '%s (%s) = %s %s', [_monitor, _probe_arg, _value, _units]) . The values for _monitor, _probe_arg, _value and _units are taken from the homonymous slots. These slots are set if DM 3.7 sends a event, but are not set if ITM 6.1 sends a TEC event. Here the msg slot is already set correctly. After this it gets changed to " () =" which is not quite helpful. The problem is for DM 3.7 you have to use this ruleset to get a proper msg slot. So ITM 6.1 either fill these slots or should use it's own classes.
Local fix
Problem summary
When DM 3.7 events were sent to TEC via ITM 6.1, the msg slot in the event gets set to " () =".
Problem conclusion
Change the sentry.rls file to check for a source of ITM before changing the msg slot. The fix for this APAR is contained in the following maintenance packages: | fix pack | 3.9.0-TIV-TEC-FP0007
Temporary fix
Comments
APAR Information
APAR number
IY92879
Reported component name
TEMA
Reported component ID
5724C04TE
Reported release
390
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-01-11
Closed date
2007-10-05
Last modified date
2007-10-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TIVOLI ENT.CONS
Fixed component ID
5698TEC00
Applicable component levels
R390 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSGMKC","label":"Tivoli Enterprise Console"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"390","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]