IBM Support

PK97877: STARTING AND STOPPING AN APPLICATION ON A Z/OS MAY RESULT IN AN INCONSISTENT APPLICATION STATE BETWEEN THE SERVANTS & ADJUNCT

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Starting and Stopping an application on a z/OS may result in an
    inconsistent application state between the Servants & Adjunct
    regions.
    The application state can only be made consistent after a server
    restart.
    .
    Set Custom Properties
    "com.ibm.ws390.management.proxy.ApplicationMgrMBeanProxy.zos.pre
    FilterCheck" to "true".
    .
    There are two way in doing so:
    o   At the CELL level
    o   At the AppServer level
    .
    At the AppServer Level
    ======================
    #  From the AdminConsole.  Select the AppServer and under
       "Server Infreastructure" select "Process Defination"
    
    #  Then select the "Control" and "Custom Properties "
    
    #  Then "NEW"  and "ADD"
    
    
      com.ibm.ws390.management.proxy.ApplicationMgrMBeanProxy.zos.
    preFilterCheck with a value of true
    
    
    
    #   Save your change by selecting "Apply"
    .
    Application servers > server1 > Process Definition > Control >
    Custom Properties >
    com.ibm.ws390.management.proxy.ApplicationMgrMBeanProxy.zos.preF
    ilterCheck
    ..
    At the Cell Level
    =================
    
    #  From the Environment tab select WebSphere Variables
    
    #  create a new variable IBM_JAVA_OPTIONS and set the value of
       this variable to
    -Dcom.ibm.ws390.management.proxy.ApplicationMgrMBeanProxy.zos.pr
    eFilterCheck=true
    
    #  Then save you change
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of WebSphere Application Server    *
    *                 V7.0                                         *
    *                                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: The ApplicationMgr did not provide a    *
    *                      facility for maintaining a consistent   *
    *                      application stop state between          *
    *                      regions on z/OS.                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Runtime components can control whether applications should
    start or stop by installing a DeployedApplicationFilter with
    the ApplicationMgr. On z/OS, each region has it's own set of
    runtime components and installed DeployedApplicationFilters.
    When an application is stopped on all regions, it is possible
    for some regions to agree to the application stop while others
    don't. This results in an inconsistent application state
    across the regions.
    

Problem conclusion

  • A flag has been introduced to enable a new behavior that will
    attempt to maintain a consistent application state among the
    regions on z/OS. A servant region will first be asked whether
    the application can stop, before an application stop is issued
    to all the regions.
    
    APAR PK97877 is currently targeted for inclusion in Service
    Level (Fix Pack) 7.0.0.7 of WebSphere Application Server V7.0.
    
    Please refer to URL:
    //www.ibm.com/support/docview.wss?rs=404&uid=swg27006970
    for Fix Pack availability.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK97877

  • Reported component name

    WEBSPHERE FOR Z

  • Reported component ID

    5655I3500

  • Reported release

    700

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-10-05

  • Closed date

    2009-10-21

  • Last modified date

    2009-12-02

  • APAR is sysrouted FROM one or more of the following:

    PK81647

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • BBGUBINF BBOUBINF
    

Fix information

  • Fixed component name

    WEBSPHERE FOR Z

  • Fixed component ID

    5655I3500

Applicable component levels

  • R700 PSY UK51554

       UP09/11/10 P F911

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS7K4U","label":"WebSphere Application Server for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
10 February 2022