IBM Support

IC74751: THE XSLT PROFILE TIMER COLUMN SHOWS INCORRECT VALUES WHEN VIEWED IN WEBGUI OR VIA COMMAND LINE INTERFACE (CLI).

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The XSLT profile timer values should be shown in
    milliseconds, but are shown with sub-microsecond resolution.
    

Local fix

Problem summary

  • Affected are customers making use of DataPower Stylesheet
    Profiling.
    
    Time values in Stylesheet Profile Status Provider were
    incorrectly not reported in milliseconds.
    
    There was a problem in the scaling function.
    The corrective factors (without the fix) are:
    0.000278 (for 9003)
    0.000354 (for 9004)
    So for a reported Time value "x" the time in milliseconds can be
    calculated as "x * 0.000354" for a 9004.
    

Problem conclusion

  • The fix is available in 3.8.0.12, 3.8.1.11 and 3.8.2.3
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC74751

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    380

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-02-28

  • Closed date

    2011-04-15

  • Last modified date

    2011-06-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R380 PSY

       UP

  • R381 PSY

       UP

  • R382 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.8","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]