APAR status
Closed as program error.
Error description
The time gap between NTP and DataPower does not adjust until the gap reached 500msec. It is expected to be adjusted even when it is less than 500msec. Event Code 0x80e0031f text: Event Code 0x80e0031f - NTP time difference in microseconds After receiving an update from the Network Time Protocol service, this is the difference in time that existed between the time the service returned and the time on the appliance in microseconds. Adjustments of greater than 0.5 seconds (500,000 microseconds) are performed by stepping the time. Smaller adjustments are made by adjusting the rate of the clock.
Local fix
Problem summary
NTP and WTX together can cause time steps instead of a gradual adjustment.
Problem conclusion
The fix will be in 3.7.3.16, 3.8.0.10, 3.8.1.9
Temporary fix
Comments
APAR Information
APAR number
IC73049
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
381
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-12-06
Closed date
2011-01-18
Last modified date
2011-01-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R373 PSY
UP
R380 PSY
UP
R381 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.8.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: