  • The following series of events will
    lead to out of order message processing when the gateway is
    configured with
    in-order processing mode. The latter mode specifies that all
    messages should be
    output in exactly the same order as they have been received from
    input queue.
    
    1. Message #1 is received and being processed.
    2. Message #2 is received and being processed.
    3. Message #2 reaches back side first, acquires an instance of
    MQQM object to
    allocate back side connection and then goes dormant waiting for
    Message #1 to
    be processed.
    4. MQQM is disabled.
    5. Message #1 reaches back side, unable to allocate MQQM object
    (it is already
    disabled) and fails.
    6. At this point processing of Message #1 considered to be
    finished and Message
    #2 proceeds without checking that Message #1 has failed.
    

Local fix

Problem summary

  • Handle all connection state changes.
    

Problem conclusion

  • The fix will be in 3.7.3.16, 3.8.0.10, 3.8.1.9, 3.8.2.1
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC72872

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    380

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-11-30

  • Closed date

    2011-01-20

  • Last modified date

    2011-01-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R373 PSY

       UP

  • R380 PSY

       UP

  • R381 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.8","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
11 February 2022