IBM Support

IC71886: HTTP REDIRECTS MAY FAIL FOR SERVICES HAVING HTTP FSH & NON-XML REQUEST TYPE WHEN ALTERNATE RULE IN ON-ERROR ACTION IS TRIGGERED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • HTTP redirects between services may fail in the following
    circumstances:
    
     - When an XML Firewall or Multi-Protocol Gateway is
       configured for non-XML request type, has an HTTP
       front side handler, and an on-error action specifying
       an alternate rule is triggered.
    
    
    The problem may not be noticed unless persistent HTTP
    connections are used.
    

Local fix

Problem summary

  • This problem will appear for any XML Firewall or Multi-Protocol
    Gateway with HTTP front side that is configured with "non-xml"
    request type and has on-error action which defines an
    alternative rule to be executed. In some cases the following
    transaction on the same persistent connection will have extra
    data from the last transaction.
    

Problem conclusion

  • The fix is in 3.8.0.9 and 3.8.1.7.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC71886

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    380

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-10-14

  • Closed date

    2010-12-02

  • Last modified date

    2011-01-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R380 PSY

       UP

  • R381 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.8","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]