APAR status
Closed as program error.
Error description
IBM WebSphere DataPower Appliance Firmware: 3.8.1.2 Decription: When using WTX binary transform with input F0F0, the output result from DataPower doesn't correct ACTUAL RESULTS <soapenv:Envelope> <soapenv:field01>0000</soapenv:field01> <soapenv:field02>00</soapenv:field02> <soapenv:field03>0000</soapenv:field03> <soapenv:field04>00</soapenv:field04> </soapenv:Envelope> EXPECTED RESULTS <soapenv:Envelope> <soapenv:field02>00</soapenv:field02> <soapenv:field04>00</soapenv:field04> </soapenv:Envelope>
Local fix
Problem summary
We were only looking for the "special value for NONE" on input when it looked like the data was invalid. We should always look for it.
Problem conclusion
This fix will be available in 3.7.3.13, 3.8.0.7, and 3.8.1.5
Temporary fix
Comments
APAR Information
APAR number
IC70236
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
380
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-07-30
Closed date
2010-09-09
Last modified date
2010-09-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R373 PSY
UP
R380 PSY
UP
R381 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.8","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
11 February 2022