IC69371: HTTP SERVICE FAILS WHEN POINTING TO SUBFOLDERS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Firmware: 3.8.0.4
    
    Problem description:
    
    Browsing datapwoer's http service, found base directory name was
    add at the
    front of file link.
    
    HOW TO REPRODUCE
    1. Import attached configuration export in bz into the domain
    you prefer. A http
    service will be created (with port number: 2118)
    2. Open your browser.
    3. Set the browser address to http://serverdns:port
       (Note that the result should display the TEST.TXT file which
    is located
    under local:///AdminFiles folder)
    4.   Click on the TEST.TXT file.  The new browser address field
    shows
    http://serverdns:2118/AdminFiles/TEST.TXT yet the browser window
    shows HTTP 404
    The Page Cannot Be Found
    5.   Now change the browsers address field to remove th
    "/AdminFiles" text to
    show http://serverdns:2118/TEST.TXT and press Enter.  Notice
    that the file can
    now be displayed.
    

Local fix

Problem summary

  • HTTP Service will now have the correct links in the directory
    listing for base directory paths that contain a subdirectory.
    

Problem conclusion

  • The fix will be in 3.7.2.13, 3.7.3.12, 3.8.0.6, 3.8.1.4 &
    3.8.2.0
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC69371

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    380

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-06-24

  • Closed date

    2010-08-06

  • Last modified date

    2010-08-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R372 PSY

       UP

  • R373 PSY

       UP

  • R380 PSY

       UP

  • R381 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.8","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
11 February 2022