APAR status
Closed as program error.
Error description
In Release 3.8.1.0, on XI50B Blade platform only, the date of battery installation cannot be read. The "show battery" CLI command in config mode does not return the correct result. The (deprecated) EnvironmentalSensors status provider does not return the correct result for battery install date. One way to read the EnvironmentalSensors status provider is through SNMP, and the SNMP MIB object dpStatusEnvironmentalSensorsbatteryinstalldate does not return the correct result.
Local fix
Problem summary
Corrected the inability to read the battery installation date on a XI50B Blade platform in 3.8.1.0.
Problem conclusion
This is fixed in the 3.8.1.1 fixpack.
Temporary fix
Comments
APAR Information
APAR number
IC69161
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
381
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-06-11
Closed date
2010-06-15
Last modified date
2010-06-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R381 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.8.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: