IBM Support

IC69010: SFTP FILE LISTING FAILS FOR A FILE OWNER WITH AN UNDERSCORE IN THE NAME

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • IBM WebSphere DataPower Appliance
    
    Firmware 3.8.0.4
    
    The SFTP file listing may fail when file attributes contain
    characters such as the following: underscore '_', left/open
    bracket '(', question mark '?', and right/close bracket ')'. For
    example, the file listing may fail if the owner of the file has
    an underscore in the name (test_user).
    
    Sample error messages logged:
    SFTP Server: Invalid listing format [-rw-r--r--   1 test_user
    other  ]
    SFTP Server: Invalid listing format [-rw-r--r--   1 testuser
    (?)  ]
    
    
    Steps to recreate
    1. Use an FTP user with underscore in the name, to PUT a file on
    the FTP server.
    2. Create a MPGW with a SFTP Front-side handler and a static
    backend to the FTP server.
    3. Use an SFTP client to connect to the SFTP Front-side handler
    and try to list the directory containing the file stored in step
    1.
    

Local fix

  • If possible, change the owner/group of the file to be listed
    

Problem summary

  • Allowed more special characters when parsing the directory
    listing.
    

Problem conclusion

  • The fix will be in 3.7.2.12, 3.7.3.11, 3.8.0.5, 3.8.1.2
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC69010

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    380

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-06-03

  • Closed date

    2010-06-21

  • Last modified date

    2010-06-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R372 PSY

       UP

  • R373 PSY

       UP

  • R380 PSY

       UP

  • R381 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.8","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information