IBM Support

PM65275: A CORE DUMP MAY OCCUR WHEN RUNNING A MAP THAT USES THE PACKAGE FUNCTION WHICH REFERENCES AN ELEMENT WITH A VALUE OF NONE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A core dump may occur when running a map that uses the
    PACKAGE() function which references an element with a value of
    NONE.
    

Local fix

  • WTXCQ - WTX00040717
    GK / GK
    Circumvention: None
    

Problem summary

  • Users Affected:
    WebSphere Transformation Extender customers using PACKAGE
    function and an item that evaluates to None.
    
    Problem Description:
    If PACKAGE function is called with an element which value is
    NONE, the following error might be seen using memory tracking
    tools:
    Read from uninitialized (rui) on thread 1:
    Attempting to read 1 byte at address 0xffffffff7fff81a3
        which is 403 bytes above the current stack pointer
    Variable is 'byChar'
    t@1 (l@1) stopped in Package at line 3716 in file "f_chars.c"
    [1] Package
    [2] FindOperand
    [3] Word_OP
    [4] FindOperand
    [5] TrimLeft
    [6] FindOperand
    [7] FindOperand
    [8] Calculate
    [9] FindOperand
    [10] Calculate
    
    
    Uninitialized read can cause undefined behaviors including
    crashes.
    
    Platforms Affected:
    ALL
    

Problem conclusion

  • Fixed code to prevent uninitialized memory read in the PACKAGE
    function.
    
    Delivered in:
    8.3.0.5, 8.4.0.3
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM65275

  • Reported component name

    WSTX

  • Reported component ID

    5724M4000

  • Reported release

    820

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-05-23

  • Closed date

    2012-06-28

  • Last modified date

    2012-07-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WSTX

  • Fixed component ID

    5724M4000

Applicable component levels

  • R830 PSY

       UP

  • R840 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSD8","label":"IBM Transformation Extender"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.2","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]