IBM Support

PM50979: AN "INVALID USER/PASSWORD" ERROR CODE 1017 MAY OCCUR WHEN ACCESSING ORACLE AQ IF CASE SENSITIVE LOGON IS SET TO ON

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • An "invalid user/password" error code 1017 may occur when
    accessing Oracle AQ if case sensitive logon set to on.
    
    The Oracle AQ adapter is forcing username and password to all
    uppercase.  In Oracle 11, if password sensitivity is set to
    on then a failure may occur.
    

Local fix

  • WTXCQ - WTX00038972
    GK / GK
    Circumvention: None
    

Problem summary

  • Users Affected:
    WebSphere Transformation Extender customers using Oracle AQ
    connecting to an Oracle 11g Server.
    
    Problem Description:
    The Oracle Client driver is reporting a login failure to the WTX
    Oracle AQ Adapter.
    
    Platforms Affected:
    ALL
    

Problem conclusion

  • The WTX AQ Adapter now retains user name and password case
    sensitivity when logging into the Oracle Server.  Before this
    fix, the Adapter would always change the user name and password
    to uppercase.  In order to work around this problem before
    getting the fix, the customer needs to ensure that the following
    system command is issued:
    alter system set sec_case_sensitive_logon = false;
    
    The current setting can be viewed by using the following
    command:
    show parameter sec_case_sensitive_logon;
    
    After this fix, the above system commands will not need to be
    used.
    
    Delivered in:
    8.1.0.6, 8.2.0.6, 8.3.0.5, 8.4.0.0
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM50979

  • Reported component name

    WTX FOR INT SER

  • Reported component ID

    5724M4010

  • Reported release

    820

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2011-10-27

  • Closed date

    2011-11-30

  • Last modified date

    2012-02-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WTX FOR INT SER

  • Fixed component ID

    5724M4010

Applicable component levels

  • R810 PSY

       UP

  • R820 PSY

       UP

  • R830 PSY

       UP

  • R840 PSY

       UP

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCKRDT","label":"WTX for Integration Servers"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.2","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
03 February 2012