IBM Support

PM48795: MATHMATICAL CALCULATIONS USING BINARY NUMBER FIELDS AS A SOURCE MAY PROVIDE INCORRECT VALUES ON THE LINUX PLATFORM

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A typetree object defined as a binary number item will display
    correctly, but any mathmatical operations using that typetree
    object when executed on the Linux platform may be missing or
    incorrect.
    
    For example, the following item:
    
    <ITEM SimpleTypeName="BinaryNumberItem"
    CategoryOrItemParent="NumberItems root" partition="NO"
    OrderSubtypes="ADDLAST"><BinaryNumber><BinFloat Length="8"/>
    <ValueRestrictions IgnoreCase="NO"
    Rule="INCLUDE"></ValueRestrictions>
    </BinaryNumber>
    
    and the following rule:
    
    = 7.12345
    
    would produce the output of:
    
    ÊÃB­i~@
    
    The following rule, (using the previous result)
    
    =10*TONUMBER(TEXT(BinaryNumberItem NumberItems:Out))
    
    ...on any other platform, would report:
    
    71.2345
    
    ...but on Linux, you would get:
    
    0.
    
    Additionally, the following rule:
    
    =10*BinaryNumberItem NumberItems:Out
    
    ...should report:
    
    71.2345
    
    However, on Linux you would get a zero length response.
    

Local fix

  • WTXCQ - WTX00038929
    PB / PB
    No known workaround.
    

Problem summary

  • Users Affected:
    WebSphere Transformation Extender customers using float
    precision numbers on Linux
    
    Problem Description:
    Float numbers are not converted correctly on Linux platform.
    "Output invalid" error may happen.
    
    Platforms Affected:
    Linux, zLinux
    

Problem conclusion

  • Correct code to properly convert float numbers on Linux
    
    Delivered in:
    8.1.0.6, 8.2.0.6, 8.3.0.5
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM48795

  • Reported component name

    WSTX

  • Reported component ID

    5724M4000

  • Reported release

    830

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2011-09-27

  • Closed date

    2011-10-14

  • Last modified date

    2012-02-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WSTX

  • Fixed component ID

    5724M4000

Applicable component levels

  • R810 PSY

       UP

  • R820 PSY

       UP

  • R830 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSD8","label":"IBM Transformation Extender"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.3","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date: