APAR status
Closed as program error.
Error description
The HIPAA Pack 4.3.2 1 compliance check map accepts non-compliant 5010X223A2 data where the 2420A NM108 has 24 instead of XX. A type 4 validation map using the HIPAA 4.3.2.1 type tree properly fails for the same data.
Local fix
WTXCQ - WTX00038525 EM / EM Circumvention: None
Problem summary
Users affected: Websphere Transformation Extender Pack for HIPAA Problem Description: HIPAA Pack 4.3.2 1 accepts non compliant 5010X223A2 data 2420A NM1 segment Platforms Affected: ALL
Problem conclusion
An extra space in a component rule in the segment tree was affecting the checking and has been removed. Delivered in HCIP 4.3.2.1
Temporary fix
Comments
APAR Information
APAR number
PM46389
Reported component name
WEBSPHERE HIPAA
Reported component ID
5724M6100
Reported release
430
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-08-25
Closed date
2011-08-30
Last modified date
2012-02-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBSPHERE HIPAA
Fixed component ID
5724M6100
Applicable component levels
R431 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSD8","label":"IBM Transformation Extender"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.3.0","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
10 February 2012