APAR status
Closed as program error.
Error description
When 5010X279A1 271 data is passed through Compliance Check it completes successfully without reporting validation errors. The same data passed through a HIPAA validation map using hipaa_x12.mtt type tree fails validation.
Local fix
WTXCQ - WTX00037998 TR / TR Circumvention: None
Problem summary
Users Affected: Websphere Transformation Extender Pack for HIPAA Problem Description: Data failed pass through validation, but passed complaince check Platforms affected: ALL
Problem conclusion
Fix was made to N4 segment in 5010X279A1 271 2100D NM1 Loop in the hipaa_x12_segment.mtt Delivered in: HCIP 4.3.2.1
Temporary fix
Comments
APAR Information
APAR number
PM42826
Reported component name
WEBSPHERE HIPAA
Reported component ID
5724M6100
Reported release
431
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-06-30
Closed date
2011-07-25
Last modified date
2011-12-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBSPHERE HIPAA
Fixed component ID
5724M6100
Applicable component levels
R431 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSD8","label":"IBM Transformation Extender"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.3.1","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
08 December 2011