PM42119: HIAPP COMPLIANCE CHECK MAP DOES NOT REJECT 5010X221A1 835 TRANSACTION WHEN MANDATORY 1000A PER_BL IS NOT PRESENT

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The HIPAA compliance check map does not reject 5010X221A1 835
    transaction when mandatory 1000A PER_BL is not present.
    
    In the HIPAA 4.3.2 hipaa_x12_type_4 type tree, the Payer N1 Loop
    has the 5th component as optional, yet within this group the 2nd
    component, PER_BL_Technical_Department PER Segment, is required.
    
    This is in the group: Payer_Identification PER Unordered_Group
    is (0:1).  The sub component of this group,
    PER_BL_Technical_Department PER Segment is (1:s).  The 0:1 and
    1:s are in conflict with one another which results in HIPAA data
    being accepted when PER_BL_Technical_Department PER Segment is
    not present when in fact it is required.
    

Local fix

  • WTXCQ - WTX00037841
    TR / TR
    Circumvention: None
    

Problem summary

  • Users affected:
    WebSphere Transformation Extender Pack for HIPAA
    
    Problem description:
    1000A PER_BL is mandatory in the 5010X221A1 835 transaction.
    
    Platforms affected :
    ALL
    

Problem conclusion

  • Made the Payer_Identification Unordered Group mandatory for
    4.3.2 and 4.3.2.1.
    
    Delivered in:
    HCIP 4.3.2.0, HCIP 4.3.2.1
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM42119

  • Reported component name

    WEBSPHERE HIPAA

  • Reported component ID

    5724M6100

  • Reported release

    430

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2011-06-21

  • Closed date

    2011-06-23

  • Last modified date

    2011-10-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBSPHERE HIPAA

  • Fixed component ID

    5724M6100

Applicable component levels

  • R431 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSD8","label":"IBM Transformation Extender"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.3.0","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
14 October 2011