APAR status
Closed as program error.
Error description
A map using a Optional WhiteSPace <OWSP> in the Terminator fails with a "Disk read error" when processing data using WTX 8.2.0.4 IF3 The map aborts with the message 'Disk read error' and 'INPUT 1 was valid but contained -1 bytes of unknown data at the end'.
Local fix
WTXCQ - WTX00037753 GK / GK Circumvention: None
Problem summary
Users Affected: WebSphere Transformation Extender customers using optional whitespace character as a part of terminator definition Problem Description: When engine validates input data, a type length is calculated wrongly resulting with the following warning: "INPUT 1 was valid but contained -X bytes of unknown data at the end" where X is some number of bytes. Due to this validation error, when the core engine uses this type to build the output, it gets DISK READ ERROR. This happens if terminator literal has optional whitespace <OWSP> character. Platforms Affected: ALL
Problem conclusion
Correct validation code to correctly calculate the size of types. Delivered in: 8.1.0.6, 8.2.0.6, 8.3.0.5
Temporary fix
Comments
APAR Information
APAR number
PM40633
Reported component name
WEBSPHERE DESIG
Reported component ID
5724M4008
Reported release
820
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-06-02
Closed date
2011-06-10
Last modified date
2011-10-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBSPHERE DESIG
Fixed component ID
5724M4008
Applicable component levels
R810 PSY
UP
R820 PSY
UP
R830 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSD8","label":"IBM Transformation Extender"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.2","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
14 October 2011