IBM Support

PM40488: WTX CRASH OR OUT OF MEMORY ERROR OCCURS DURING XML XERCES VALIDATION OF INVALID DATA WHEN USING COMPONENT RULES

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A WTX crash or out of memory error occurs during XML Xerces
    validation of invalid data when using component rules.
    
    On Windows the map ends with a 'Not enough memory' error.
    
    On Unix the map ends with a Bus Error(coredump).
    

Local fix

  • WTXCQ - WTX00037708
    GK / PB
    Circumvention: None
    

Problem summary

  • Users Affected:
    WebSphere Transformation Extender customers using Xerces
    validation
    
    Problem Description:
    After XML validation fails, code executes a component rule for
    an element that is not built causing read from non-initialized
    memory address. Application may crash or fail with out of
    memory error.
    
    Platforms Affected:
    ALL
    

Problem conclusion

  • If XML validation fails, validation component rules should not
    be executed.
    
    Delivered in:
    8.2.0.6, 8.3.0.5
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM40488

  • Reported component name

    WSTX

  • Reported component ID

    5724M4000

  • Reported release

    820

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2011-06-01

  • Closed date

    2011-06-29

  • Last modified date

    2011-10-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WSTX

  • Fixed component ID

    5724M4000

Applicable component levels

  • R820 PSY

       UP

  • R830 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSD8","label":"IBM Transformation Extender"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.2","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]