APAR status
Closed as program error.
Error description
Compliance Check incorrectly produces a failure report in the 999 for an 837 D2 segment where the IK4 reports an element that does not exist.
Local fix
WTXCQ - WTX00037551 PVB / PVB Circumvention: None
Problem summary
Users affected: Websphere Transformation Extender Pack for HIPAA Problem Description: DN2 failing Type 1 validation incorrectly Platforms affected: ALL
Problem conclusion
5010 portion of the segment tree had the utility Text element field in the DN2 segment as mandatory and also the rule on it was incorrect Delivered in: HCIP 4.3.2.0, HCIP 4.3.2.1
Temporary fix
Comments
APAR Information
APAR number
PM38753
Reported component name
WEBSPHERE HIPAA
Reported component ID
5724M6100
Reported release
431
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-05-10
Closed date
2011-05-25
Last modified date
2011-09-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBSPHERE HIPAA
Fixed component ID
5724M6100
Applicable component levels
R431 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSD8","label":"IBM Transformation Extender"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.3.1","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
19 September 2011